Parameter | Choices/Defaults | Comments | |
---|---|---|---|
app_service string | The iApp service to be associated with this profile. When no service is specified, the default is None. | ||
debug boolean |
| Specifies whether the monitor sends error messages and additional information to a log file created and labeled specifically for this monitor. When yes the system redirects error messages and additional information to the /var/log/monitors/<monitor_name>-<node_name>-<port>.log file. | |
description string | The description of the monitor. | ||
domain string | Specifies the domain name to check. | ||
interval integer | The interval specifying how frequently the monitor instance of this template will run. This value must be less than the timeout value.When creating a new monitor, if this parameter is not provided, the default 5 will be used. | ||
ip string | IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'. | ||
manual_resume boolean |
| Specifies whether the system automatically changes the status of a resource to enabled at the next successful monitor check. If you set this option to yes , you must manually re-enable the resource before the system can use it for load balancing connections.When creating a new monitor, if this parameter is not specified, the default value is no .When yes , specifies you must manually re-enable the resource after an unsuccessful monitor check.When no , specifies the system automatically changes the status of a resource to enabled at the next successful monitor check. | |
name string / required | Specifies the name of the monitor. | ||
parent string | The parent template of this monitor template. Once this value has been set, it cannot be changed. When creating a new monitor, if this parameter is not specified, the default is the system-supplied smtp monitor. | ||
partition string | Default: "Common" | Device partition to manage resources on. | |
port string | Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'. If specifying an IP address, you must specify a value between 1 and 65535. | ||
provider dictionary added in 1.0.0 of f5networks.f5_modules | A dict object containing connection details. | ||
auth_provider string | Configures the auth provider for to obtain authentication tokens from the remote device. This option is really used when working with BIG-IQ devices. | ||
no_f5_teem boolean |
| If yes , TEEM telemetry data is not sent to F5.You may omit this option by setting the environment variable F5_TELEMETRY_OFF .Previously used variable F5_TEEM is deprecated as its name was confusing. | |
password string / required | The password for the user account used to connect to the BIG-IP. You may omit this option by setting the environment variable F5_PASSWORD .aliases: pass, pwd | ||
server string / required | The BIG-IP host. You may omit this option by setting the environment variable F5_SERVER . | ||
server_port integer | Default: 443 | The BIG-IP server port. You may omit this option by setting the environment variable F5_SERVER_PORT . | |
timeout integer | Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error. | ||
transport string |
| Configures the transport connection to use when connecting to the remote device. | |
user string / required | The username to connect to the BIG-IP with. This user must have administrative privileges on the device. You may omit this option by setting the environment variable F5_USER . | ||
validate_certs boolean |
| If no , SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.You may omit this option by setting the environment variable F5_VALIDATE_CERTS . | |
state string |
| When present , ensures the monitor exists.When absent , ensures the monitor is removed. | |
time_until_up integer | Specifies the amount of time in seconds after the first successful response before a node will be marked up. A value of 0 will cause a node to be marked up immediately after a valid response is received from the node.If this parameter is not provided when creating a new monitor, then the default value will be 0 . | ||
timeout integer | The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this to any number, however, it should be 3 times the interval number of seconds plus 1 second. If this parameter is not provided when creating a new monitor, the default value will be 31 . | ||
up_interval integer | Specifies the interval for the system to use to perform the health check when a resource is up. When 0 , specifies the system uses the interval specified in interval to check the health of the resource.When any other number, enables you to specify a different interval to use when checking the health of a resource that is up. When creating a new monitor, if this parameter is not provided, the default 0 will be used. |
Note
- name: Create SMTP Monitor bigip_monitor_smtp: state: present ip: 10.10.10.10 name: my_smtp_monitor domain: foo.com provider: server: lb.mydomain.com user: admin password: secret delegate_to: localhost - name: Remove SMTP Monitor bigip_monitor_smtp: state: absent name: my_smtp_monitor provider: server: lb.mydomain.com user: admin password: secret delegate_to: localhost
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
app_service string | changed | The iApp service associated with this monitor. Sample: /Common/good_service.app/good_service |
debug boolean | changed | Whether the monitor sends error messages and additional information to a log file created and labeled specifically for this monitor. |
description string | changed | The description of the monitor. Sample: Important Monitor |
domain string | changed | Specifies the domain name to check. Sample: bigipinternal.com |
interval integer | changed | The new interval in which to run the monitor check. Sample: 2 |
ip string | changed | The new IP of IP/port definition. Sample: 10.12.13.14 |
manual_resume boolean | changed | Specifies whether the system automatically changes the status of a resource to up at the next successful monitor check. Sample: True |
parent string | changed | The parent monitor. Sample: /Common/foo_smtp |
port string | changed | Alias port or service for the monitor to check, on behalf of the pools or pool members with which the monitor is associated. Sample: 80 |
time_until_up integer | changed | The new time in which to mark a system as up after first successful response. Sample: 2 |
timeout integer | changed | The new timeout in which the remote system must respond to the monitor. Sample: 10 |
up_interval integer | changed | Interval for the system to use to perform the health check when a resource is up. |