W3cubDocs

/Ansible 2.11

dellemc.openmanage.dellemc_configure_idrac_eventing – Configures the iDRAC eventing related attributes

Note

This plugin is part of the dellemc.openmanage collection (version 3.0.0).

To install it use: ansible-galaxy collection install dellemc.openmanage.

To use it in a playbook, specify: dellemc.openmanage.dellemc_configure_idrac_eventing.

New in version 1.0.0: of dellemc.openmanage

Synopsis

  • This module allows to configure the iDRAC eventing related attributes.

Requirements

The below requirements are needed on the host that executes this module.

  • omsdk
  • python >= 2.7.5

Parameters

Parameter Choices/Defaults Comments
address
string
Email address for SNMP Trap.
alert_number
integer
Alert number for Email configuration.
authentication
string
    Choices:
  • Enabled
  • Disabled
Simple Mail Transfer Protocol Authentication.
custom_message
string
Custom message for SNMP Trap reference.
destination
string
Destination for SNMP Trap.
destination_number
integer
Destination number for SNMP Trap.
email_alert_state
string
    Choices:
  • Enabled
  • Disabled
Whether to Enable or Disable Email alert.
enable_alerts
string
    Choices:
  • Enabled
  • Disabled
Whether to Enable or Disable iDRAC alerts.
idrac_ip
string / required
iDRAC IP Address.
idrac_password
string / required
iDRAC user password.

aliases: idrac_pwd
idrac_port
integer
Default:
443
iDRAC port.
idrac_user
string / required
iDRAC username.
password
string
Password for SMTP authentication.
share_mnt
string
Local mount path of the network share with read-write permission for ansible user. This option is mandatory for Network Share.
share_name
string / required
Network share or a local path.
share_password
string
Network share user password. This option is mandatory for CIFS Network Share.

aliases: share_pwd
share_user
string
Network share user in the format 'user@domain' or 'domain\user' if user is part of a domain else 'user'. This option is mandatory for CIFS Network Share.
smtp_ip_address
string
SMTP IP address for communication.
smtp_port
string
SMTP Port number for access.
snmp_trap_state
string
    Choices:
  • Enabled
  • Disabled
Whether to Enable or Disable SNMP alert.
snmp_v3_username
string
SNMP v3 username for SNMP Trap.
username
string
Username for SMTP authentication.

Notes

Note

  • Run this module from a system that has direct access to DellEMC iDRAC.
  • This module supports check_mode.

Examples

---
- name: Configure the iDRAC eventing attributes
  dellemc.openmanage.dellemc_configure_idrac_eventing:
       idrac_ip:   "192.168.0.1"
       idrac_user: "user_name"
       idrac_password:  "user_password"
       share_name: "192.168.0.1:/share"
       share_password:  "share_user"
       share_user: "share_password"
       share_mnt: "/mnt/share"
       destination_number: "2"
       destination: "1.1.1.1"
       snmp_v3_username: "None"
       snmp_trap_state: "Enabled"
       email_alert_state: "Disabled"
       alert_number: "1"
       address: "[email protected]"
       custom_message: "Custom Message"
       enable_alerts: "Disabled"
       authentication: "Enabled"
       smtp_ip_address: "192.168.0.1"
       smtp_port: "25"
       username: "username"
       password: "password"

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
error_info
dictionary
on HTTP error
Details of the HTTP Error.

Sample:
{'error': {'@Message.ExtendedInfo': [{'Message': 'Unable to process the request because an error occurred.', 'MessageArgs': [], 'MessageId': 'GEN1234', 'RelatedProperties': [], 'Resolution': 'Retry the operation. If the issue persists, contact your system administrator.', 'Severity': 'Critical'}], 'code': 'Base.1.0.GeneralError', 'message': 'A general error has occurred. See ExtendedInfo for more information.'}}
eventing_status
dictionary
success
Configures the iDRAC eventing attributes.

Sample:
{'CompletionTime': '2020-04-02T02:43:28', 'Description': 'Job Instance', 'EndTime': None, 'Id': 'JID_12345123456', 'JobState': 'Completed', 'JobType': 'ImportConfiguration', 'Message': 'Successfully imported and applied Server Configuration Profile.', 'MessageArgs': [], 'MessageId': 'SYS053', 'Name': 'Import Configuration', 'PercentComplete': 100, 'StartTime': 'TIME_NOW', 'Status': 'Success', 'TargetSettingsURI': None, 'retval': True}
msg
string
always
Successfully configured the iDRAC eventing settings.

Sample:
Successfully configured the iDRAC eventing settings.


Authors