Note
This plugin is part of the dellemc.openmanage collection (version 3.0.0).
To install it use: ansible-galaxy collection install dellemc.openmanage
.
To use it in a playbook, specify: dellemc.openmanage.redfish_powerstate
.
New in version 2.1.0: of dellemc.openmanage
The below requirements are needed on the host that executes this module.
Parameter | Choices/Defaults | Comments |
---|---|---|
baseuri string / required | IP address of the target out-of-band controller. For example- <ipaddress>:<port>. | |
password string / required | Password of the target out-of-band controller. | |
reset_type string / required |
| This option resets the device. If ForceOff , Turns off the device immediately.If ForceOn , Turns on the device immediately.If ForceRestart , Turns off the device immediately, and then restarts the device.If GracefulRestart , Performs graceful shutdown of the device, and then restarts the device.If GracefulShutdown , Performs a graceful shutdown of the device, and the turns off the device.If Nmi , Sends a diagnostic interrupt to the device. This is usually a non-maskable interrupt (NMI) on x86 device.If On , Turns on the device.If PowerCycle , Performs power cycle on the device.If PushPowerButton , Simulates the pressing of a physical power button on the device.When a power control operation is performed, which is not supported on the device, an error message is displayed with the list of operations that can be performed. |
resource_id string | The unique identifier of the device being managed. For example- https://<baseuri>/redfish/v1/Systems/<resource_id>. This option is mandatory for base_uri with multiple devices. To get the device details, use the API https://<baseuri>/redfish/v1/Systems. | |
username string / required | Username of the target out-of-band controller. |
Note
check_mode
.--- - name: Manage power state of the first device dellemc.openmanage.redfish_powerstate: baseuri: "192.168.0.1" username: "username" password: "password" reset_type: "On" - name: Manage power state of a specified device dellemc.openmanage.redfish_powerstate: baseuri: "192.168.0.1" username: "username" password: "password" reset_type: "ForceOff" resource_id: "System.Embedded.1"
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
error_info dictionary | on http error | Details of the HTTP error. Sample: {'error': {'@Message.ExtendedInfo': [{'Message': 'Unable to complete the operation because the resource /redfish/v1/Systems/System.Embedded.1/Actions/ComputerSystem.Reset entered in not found.', 'MessageArgs': ['/redfish/v1/Systems/System.Embedded.1/Actions/ComputerSystem.Reset'], '[email protected]': 1, 'MessageId': 'IDRAC.2.1.SYS403', 'RelatedProperties': [], '[email protected]': 0, 'Resolution': 'Enter the correct resource and retry the operation. For information about valid resource, see the Redfish Users Guide available on the support site.', 'Severity': 'Critical'}], 'code': 'Base.1.5.GeneralError', 'message': 'A general error has occurred. See ExtendedInfo for more information'}} |
msg string | always | Overall status of the reset operation. Sample: Successfully performed the reset type operation 'On'. |
© 2012–2018 Michael DeHaan