Note
This plugin is part of the netapp_eseries.santricity collection (version 1.1.0).
To install it use: ansible-galaxy collection install netapp_eseries.santricity
.
To use it in a playbook, specify: netapp_eseries.santricity.na_santricity_nvme_interface
.
Parameter | Choices/Defaults | Comments |
---|---|---|
address string | The IPv4 address to assign to the NVMe interface | |
api_password string / required | The password to authenticate with the SANtricity Web Services Proxy or Embedded Web Services API. | |
api_url string / required | The url to the SANtricity Web Services Proxy or Embedded Web Services API. Example https://prod-1.wahoo.acme.com:8443/devmgr/v2 | |
api_username string / required | The username to authenticate with the SANtricity Web Services Proxy or Embedded Web Services API. | |
channel integer | This option specifies the which NVMe controller channel to configure. The list of choices is not necessarily comprehensive. It depends on the number of ports that are available in the system. The numerical value represents the number of the channel (typically from left to right on the HIC), beginning with a value of 1. | |
config_method string |
| The configuration method type to use for this interface. Only applicable when configuring RoCE dhcp is mutually exclusive with address, subnet_mask, and gateway. |
controller string |
| The controller that owns the port you want to configure. Controller names are presented alphabetically, with the first controller as A and the second as B. |
gateway string | The IPv4 gateway address to utilize for the interface. Only applicable when configuring RoCE Mutually exclusive with config_method=dhcp
| |
mtu integer | Default: 1500 | The maximum transmission units (MTU), in bytes. Only applicable when configuring RoCE This allows you to configure a larger value for the MTU, in order to enable jumbo frames (any value > 1500). Generally, it is necessary to have your host, switches, and other components not only support jumbo frames, but also have it configured properly. Therefore, unless you know what you're doing, it's best to leave this at the default. aliases: max_frame_size |
speed string | Default: "auto" | This is the ethernet port speed measured in Gb/s. Value must be a supported speed or auto for automatically negotiating the speed with the port. Only applicable when configuring RoCE The configured ethernet port speed should match the speed capability of the SFP on the selected port. |
ssid string | Default: 1 | The ID of the array to manage. This value must be unique for each array. |
state string |
| Whether or not the specified RoCE interface should be enabled. Only applicable when configuring RoCE |
subnet_mask string | The subnet mask to utilize for the interface. Only applicable when configuring RoCE Mutually exclusive with config_method=dhcp
| |
validate_certs boolean |
| Should https certificates be validated? |
Note
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
msg string | on success | Success message Sample: The interface settings have been updated. |
© 2012–2018 Michael DeHaan
© 2018–2021 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.11/collections/netapp_eseries/santricity/na_santricity_nvme_interface_module.html